Shower stalls that are 60 inches 1525 mm wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space.
Ada shower head location.
Controls with anti scald pressure balanced or similar features should be used.
If only 48 inches of clearance is provided in the shower stall a simple design mistake is to put the shower head on the wrong wall.
The ada states that the controls can be on the back wall or on either side wall.
A grab bar 24 inches 610 mm long minimum shall be installed on the control end wall at the front edge of the bathtub.
In standard roll in type shower compartments the controls faucets and shower spray unit shall be located above the grab bar but no higher than 48 inches 1220 mm above the shower floor.
A fixed shower head can be used in placed of a handheld shower as long as it is positioned 48 inches maximum above the finished floor.
In standard roll in shower compartments with seats the control must be located on the back wall above the seat and no more than 27 inches 685mm from the adjacent side wall.
The control location must be above the grab bar fig.
Shower compartments shall comply with 608.
Carries the finest in ada compliant handicap shower systems including symmons ada shower mixing valves delta handicap ada grab bar hand shower kits moen ada compliant shower valves moen hand shower ada compliant mixing valves hand shower hoses ada grab bar for mounting hand showers for commercial or residential handicap.
The overall understanding though is that it has to be within an arm s reach from the seat.
He said this wasn t code.
Bathtubs without permanent seats.
Shower head location as shown in fig 1 the 48 inches of clearance is measured from the control wall i e.
1 pdh steven liescheidt p e ccs ccpr continuing education and development inc.
Ada compliant hand held showers.
The wall with the shower head.
If the unit is the type that can be used as a fixed or handheld shower head the hose should be a minimum of 59 inches long.
Specifically if i installed a shower valve and head on the back wall of the shower assuming three walls would that be allowed.
Plumbing guidelines for ada accessibility course no.
9 greyridge farm court stony point ny 10980 p.
The inspector doesn t like that the owner or future owner s for that matter would have to reach through the spray of the shower to turn it on and off or make adjustments to the shower.
Great leeway is given on where to place the control valve.