The americans with disabilities act requirements for a bathroom with a shower are 36 by 36 inches for a transfer shower and 30 by 60 inches for a roll in shower.
Ada shower requirements.
Other requirements are a 1 2 inch shower curb 60 inch shower hose grab bars and seat opposite the shower control.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Maximum force applied to operate the control is also specified.
A person in a wheelchair should be able to roll up next to the shower adjust the single lever handle controls from the outside and then use the grab bars to move to the seat inside the shower unit.
The controls must be operated with one hand only and cannot bind the wrist.
The controls cannot pinch or bind skin or fingers.
The ada specified the criteria to operate all controls which includes the shower valve.
An ada roll in shower must be at least 60 x 30 inside dimension.
Grab bars must have round.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
Department of justice 1.
No more than 5 foot pounds of pressure can be used to operate the control.
In a 36 inch by 36 inch transfer type shower compartment the person must move from a wheelchair to a shower seat controls including the valve faucet and shower spray unit are to be installed on the wall opposite the seat no less than 38 inches and no more than 48 vertical inches from the floor.
Ada compliant showers are one piece units that have grab bars and a built in or fold up seat.
The ada also requires a shower spray unit with a hose of at least 60 inches that can be used as either a fixed shower head or hand held unit.
Alternate roll in type shower compartments shall be 36 inches 915 mm wide and 60 inches 1525 mm deep minimum clear inside dimensions measured at center points of opposing sides.
These shall be located on the control wall no more than 15 inches from the center line of the seat and extending toward the compartment s opening.
A 36 inch 915 mm wide minimum entry shall be provided at one end of the long side of the compartment.
According to the ada transfer showers must have at least a 36 inch wide.
Or for answers to.
An ada transfer shower must have an inside dimension of 36 x 36.
References united states access board.
The ada guidelines indicate that showers must have certain clear inside dimensions but there are two acceptable styles.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Ada standards for accessible design can be downloaded from www ada.