Figure 308 2 2 obstructed high forward reach 308 3 side reach.
Ada sink reach requirements.
If the high forward reach is over an obstruction reach and clearances shall be as shown in here under.
This places limits on the height of the sink and its position on the counter.
When the reach depth is over 20 inches deep a reach range of 44 inches applies.
The minimum low forward reach is 15 in 380 mm.
The high forward reach shall be 48 inches 1220 mm maximum where the reach depth is 20 inches 510 mm maximum.
To be ada compliant every fixture in the bathroom including the sink must be accessible to a person in a wheelchair.
A 48 inch high limitation is required for all accessories except those mounted over obstructions including lavatory fixtures which are up to 20 inches deep.
Sink drains are located at the rear instead of the middle.
A taller counter cannot be used if a side approach reach range is required.
The sink should not be connected at an extremely high location where the disabled individual cannot reach it.
Faucets and soap dispensers must meet ada reach range and mounting height requirements.
A side approach reach range is more restrictive than a forward approach.
What are ada sink and faucet requirements.
Requirements addressed reach ranges 15 2 protruding objects 15 3 handrails at ramps and stairs 15 4 drinking fountains and water coolers 15 5 water closets 15 6 toilet stalls 15 7 lavatories and mirrors 15 8 storage 15 9 and fixed or built in seating and tables 15 10.
If the clear floor space only allows forward approach to an object the maximum high forward reach allowed shall be 48 in 1220 mm.
According to ada accessibility guidelines ada compliant kitchen sinks must sit no higher than 34 inches above the floor and have shallow bowls between 5 and 6 1 2 inches deep.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
It is also important to know that countertops in such spaces must be no higher than 34 and no deeper than 24.
This section shows a 3 0 tall counter.
For one thing the height of the obstruction must only be 34 a f f.
The sink should also be 11 to 25 inches deep and 30 inches wide.
More specifically it should not be higher than 34 inches from the floor and should have a 27 inches high clearance from the knee.